The ultrasonic preamplifier models for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation provide very low noise amplification of ultrasonic signals.
     

Описание:

Olympus wideband series of Panametrics AC coupled, broadband preamplifiers provides very low noise amplification of ultrasonic signals ranging from 500 Hz to greater than 40 MHz. Specifically designed for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation, our preamplifiers are a cost-effective solution in general applications requiring high gain/low-noise amplification of low amplitude ultrasonic signals.

Our preamplifiers are ruggedly housed, completely self-contained, simple to operate, battery or AC powered units. They offer performance features such as very low noise (5 µV peak-to-peak noise referred to the input in Model 5660B), input protection for high voltage transients such as transducer excitation pulses, and the ability to drive long coaxial cables (greater than 500 feet or 152 meters with Models 5660B and 5660C). Both fixed gain and switchable gain versions are available, and custom units with special gain or bandwidth are available on special order.

Applications

Certain ultrasonic applications require the addition of a separate preamplifier unit to standard test systems in order to provide the additional gain or broadband signal-to-noise enhancement necessary for optimum signal acquisition. This is often the case in industrial applications involving flaw detection or thickness gaging of thick sections of materials exhibiting high ultrasonic attenuation such as nodular cast iron, brass, bronze, austenitic steel, rubber, Teflon®, or reinforced composites. A preamplifier is also an important component of acoustic emission test systems that require amplification of low signal amplitude events and the ability to drive long cables from remotely located sensors. 
Panametrics preamplifiers have also been used in many widely diversified research applications including seismic studies, determination of the size and number versus scattered frequency relationship for acoustic scatterers in water (gas bubbles, zooplankton), crack detection in graphite vacuum arc-melt electrodes, and biological tissue analysis.

MODEL 5682

The Model 5682 Ultrasonic Preamplifier provides low noise amplification of ultrasonic signals ranging from 500 KHz to 25 MHz. The preamplifier, housed in a rugged enclosure, is very small and lightweight making it ideally suited for remote applications. The preamplifier can be powered with either a single 9 V battery for up to 50 hours of continuous operation or a local 9 V to 13 V DC supply (customer supplied). When battery operated, a multicolored LED provides feedback on battery status. This preamplifier is ideal for AUT and TOFD scanning. 

Inclusions: The unit is supplied with one 9 V alkaline battery. All cables are sold separately and are offered in a variety of lengths and connector styles to accommodate transducer, instrumentation, and applications requirements.

Specifications*

MODEL5660B5660C5662567056765678
Voltage Gain 
(Inverting)
40 and 60 dB 
Switchable 
(RL > 1K ohm)
40 and 60 dB 
Switchable 
(RL > 1K ohm)
34 and 54 dB 
Switchable 
(RL = 50 ohm)
40 dB 
Fixed 
(RL = 50 ohm)
40 dB 
Fixed 
(RL = 50 ohm)
40 dB 
Fixed 
(RL = 50 ohm)
Bandwidth 
(-3dB)
20 kHz - 
2 MH
500 Hz - 
2 MHz
50 kHz - 
5 MHz
50 kHz - 
10 MHz
50 kHz - 
20 MHz
200 kHz - 
40 MHz
Equivalent Input 
Noise
5 µV p-p5 µV p-p10 µV p-p15 µV p-p20 µV p-p30 µV p-p
Input 
Resistance
1M ohm1M ohm100K ohm100K ohm100K ohm100K ohm
Input 
Capacitance 
(pf)
approx. 320approx. 320approx. 80approx. 80approx. 80approx. 80
Input
Protection300 V peak (Pulse Width <2 µs, 1% Maximum Duty Cycle)
Output5 V p-p (RL > 1 K ohm)
Voltage2 V p-p (RL = 50 ohm)2 V p-p (RL = 50 ohm)
Output
Impedance

50 ohms in series with 4.7 fd

Max. Output>500' (152 m)50' (15 m)
Power16 V ± 2 V supplied by 4 Alkaline 9 V, 655 mAh batteries
RequirementsLine operated units available. Add /110 VAC, /115 VAC, or /230 VAC to the Model Number (e.g. 5675/115 VAC).
Current 
Consumption
28 mA28 mA28 mA32 mA32 mA36 mA
Battery 
Life
>40 hrs>40 hrs>40 hrs>35 hrs>35 hrs>35 hrs
Dimensions3" W x 2" H x 5" D (76 mm W x 51 mm H x 127 mm D)
Weight

1.4 lbs. (0.64 kg)

Operating 
Temperature
32° F to 122° F (0° C to 50° C)

*All specifications are subject to change without notice.

NEW - Model 5682 Ultrasonic Preamplifier

Voltage Gain: 30 dB @ 10 MHz 
HighPassRollover: 0.5 MHz +/- 0.1 MHz 
LowPassRollover: 31 MHz +/-1 MHz 
Equivalent Input Noise: 11.5 µV RMS 
Input Impedance: Nominally 700 ohms 
Output Impedance: Nominally 50 ohms 
Output Voltage: 2.5 V pk-pk 
Protection: 500 V peak 
Current Consumption: Nominally 14 mA 
Power: 9 V alkaline battery or 9-13 V DC input (toggle switch) 
Power Monitor: Three color LED for continuous power level indications 
• Green: 7.0 - 9.0 V 
• Yellow: 6.5 - 7 V 
• Red: 5.0 - 6.5 V 
• No light: <5.0 V (Low charge, replace battery) 
BatteryLife:
>50 hours continuous operation 
Connectors: Lemo® 00 Type 
Dimensions: 2.25" x 4.3" x 1.1", 
57.15 mm x 109.22 mm x 27.94 mm 
Weight:
6.4 oz, 181 gr with battery; 
4.8 oz, 136 gr without battery 
Operating Temperature:
32° F to 122° F; 
0° C to 50° C 
Environmental: IP65

Передовые решения неразрушающего контроля

Контроль сварных соединений Коррозионный мониторинг Технология направленных волн Aerospace Inspection Solutions Stress Corrosion Cracking Solutions Контроль композитных материалов Промышленные сканеры Экспресс-диагностика трубопроводов

Дефектоскопы

Портативные ультразвуковые дефектоскопы Вихретоковые дефектоскопы Оборудование с фазированными решётками BondTesting Матричные вихретоковые дефектоскопы Технология направленных волн Генераторы-приёмники Датчики и преобразователи

Интегрированные системные решения в области НК

Контрольно-измерительные системы
Системы диагностики прутков Системы диагностики трубопроводов

Толщиномеры

Преобразователи и комплектующие

Компоненты микроскопов

Modular Microscope Assemblies Optical Microscope Frames Optical Microscope Modules

Оптические измерительные системы

Лазерные конфокальные микроскопы Опто-цифровые микроскопы

Видеоскопы, бороскопы

Видеоскопы Промышленные фиброскопы Стандартные жёсткие бороскопы Программное обеспечение для генерации отчетов Источники света Системы прокрутки

Высокоскоростные видеокамеры

Анализаторы XRF и XRD

Настольные XRD/XRF анализаторы
Переносной XRF-анализатор Портативный XRF-анализатор DELTA Портативный дифрактометр (XRD) Промышленный XRF-анализатор Тестовый стенд XRF

Микроскопия

Semiconductor & Flat Panel Display Inspection Инвертированные металлургические микроскопы Лазерные конфокальные микроскопы Модульные микроскопы Объективы Опто-цифровые микроскопы Поляризационные микроскопы Программное обеспечение для анализа изображений Прямые металлургические микроскопы Стерео микроскопы Цифровые камеры

Применение НК

Техподдержка