MultiScan MS5800 для контроля трубMulti-technology system that offers eddy current, magnetic flux leakage, remote field and IRIS ultrasound technologies.
Описание:The MultiScan MS5800 is a multi-technology system offering these technologies:
MS 5800E
|
EC/RFT/MFL/UT | |
Setup wizard | Easy configuration for tube inspection with conventional probes |
Automatic calibration | Simultaneous calibration of all channels and depth curves |
Data file storage | Any PC-compatible media |
Printing | Screen dump, acquisition, and setup reports to any Microsoft® Windows XP®-compatible printer |
UT | |
Measurement mode | Wall thickness: IRIS (immersion) |
Setup display | A-scan |
Profilometry display | Wall thickness, ID and OD color C‑scans, B-scan for tube circumferential cross section and axial section |
Cursors | Cross-section cursors and manual pit-sizing cursors |
Measurement | Wall loss (%), remaining wall, and statistics on tube geometry (minimum, maximum, average) |
Software Requirements | |
Operating system | Microsoft Windows XP Pro |
Hardware requirements | 2 GHz Pentium® with 2 GB RAM, 1 GB of free space on a hard disk, 1024 × 768 display resolution |
ХАРАКТЕРИСТИКИ
General | |
Power | 120 VAC or 220 VAC ±10%, automatic selection, 48 Hz to 63 Hz |
Size (excluding handle) | 45 cm x 30 cm x 22 cm |
Weight | Maximum weight with all modules installed: 12.8 kg |
Environment | -20°C to 45°C for ambient operation; -20°C to 70°C storage; 95% relative humidity, noncondensing |
Computer interface | 100Base-T Fast Ethernet |
Eddy Current Testing | |
Probe inputs | Four independent differential inputs, and up to 64 multiplexed inputs (16 time slots) with MUX-PKG-MS (U8780060) |
ECT channels | 16 simultaneously (4 inputs x 4 frequencies);
256 in super-multiplexed mode (with 16 time slots) |
Number of frequencies | Up to eight frequencies |
Frequency range | Adjustable from 20 Hz to 6 MHz |
Acquisition rate | 40 kHz per channel (in conventional mode);
14 kHz divided by the number of time slots (in multiplexed mode) |
Supported probes | The universal connector supports all standard differential and absolute bobbin, impedance, transmit-receive, and rotating probes.
(Adaptor cable might be required.) |
Probe balancing | True electronic probe balancing. A separate external reference probe is not required for absolute channels. |
Output voltage | 20 Vp-p per generator (2 outputs) |
Output current | 1 A (peak) |
Real-time alarms | Eight independent alarms (raw channels only) |
Encoders | Two quadrature encoders and digital inputs |
Remote Field Testing, Near Field, and Magnetic Flux Leakage | |
Probe inputs | Four independent inputs for RFT/NFT
Four independent inputs for MFL |
RFT/NFT channels | 16 simultaneously (4 inputs x 4 frequencies);
64 in multiplexed mode for NFT (4 inputs x 16 time slots) and eight for RFT (4 inputs x 2 time slots) |
MFL channels | Four simultaneously
64 in multiplexed mode (4 inputs x 16 time slots) |
Number of frequencies | Up to four frequencies (RFT only) |
Frequency range | Adjustable from 20 Hz to 250 kHz |
Acquisition rate | 40 kHz per channel (in conventional mode);
14 kHz divided by the number of time slots (in multiplexed mode) |
Supported probes | Supports any differential and absolute probes with a single exciter, dual exciters, dual pickup, near field, and magnetic flux leakage.
(Adaptor cable might be required.) |
Probe balancing | True electronic probe balancing |
Output voltage | 20 Vp-p per generator (2 outputs) |
Output current | 1 A (peak) |
Analog output | X and Y components of the first input |
Real-time alarms | Eight independent alarms (raw channels only) |
Encoders | Two quadrature encoders or digital inputs |
Ultrasonic IRIS testing | |
Number of pulsers/receivers | One channel in pulse-echo mode |
System bandwidth | 0.5 MHz to 25 MHz |
Sampling rate | 8-bit, 100 MHz |
Transducer frequencies | 1 MHz to 20 MHz |
Pulse repetition rate | Up to 20 kHz |
Dynamic gain (linear amplifier) | 70 dB, 1 dB steps |
A-scan length | 32 to 8,092 points |
Pulse voltage | 50 V to 300 V, 1 V steps |
High-pass filter | None, 2 MHz, 5 MHz, 10 MHz |
Data-acquisition synchronization | Time, continuous, position, or external |
Encoders | Two quadrature encoders and digital inputs (requires MultiView 6.1 or higher) |